RAYTEC Dental Radiographic Developer 475ml - Caithec
em até 1x sem juros de R$ 10,27
Payment methods
RAYTEC Dental Radiographic Developer 475ml - Caithec
em até 1x sem juros de R$ 10,27
RAYTEC - Dental Radiographic Developer
RAYTEC - DENTAL RADIOGRAPHIC DEVELOPER is used to develop the examination image on film, being a ready-to-use dental radiographic developer. It ensures faster development with greater durability. The developer, combined with a fixer, allows the image extracted from the patient to be transferred to film so that the examination can be viewed in any location with light. Ready to use.
Presentation Form: 475 ml bottles.
Storage and Conservation:
- Store at room temperature, protected from light and heat;
- Keep the packaging hermetically closed after use, in a clean, dry place;
- Keep in a dry and ventilated place;
- Dispose of the product in accordance with local legislation, ensuring its complete decomposition to prevent its reuse and environmental damage.
Instructions for use:
- The Developer together with the Fixer allows the image to be transferred to radiographic film.
- The development and fixing time can vary from 1 to 5 minutes depending on the ambient temperature;
- The colder the film, the longer the film must remain in contact with the developer to obtain the image. The recommended rinsing time after developing should be 0.5 minutes, and the recommended rinsing time after using the developer is 1 minute.
- Containers containing developer and fixer solutions should be kept covered when not in use, as their chemical composition oxidizes in air. The water used for the intermediate wash should be changed daily;
- Ready to use in small containers, tailored to the user's needs. Suitable for manual development with visual control at room temperature.
Caution: The condition and temperature of the developer, agitation, X-ray exposure time, and film sensitivity are factors that determine the development speed and the resulting desired image quality. It is important not to compensate for solution wear with increased X-ray exposure.
Precautions and Warnings:
- Potentially irritating to mucous and skin tissue. May cause discomfort, irritation, and/or allergic reactions. Wash affected areas thoroughly with water. If swallowed, seek medical help immediately.
- Product for professional use only;
- Keep out of reach of children;
- May stain fabrics with natural fibers;
- Do not reuse this packaging.
Approximate dimensions and weights
With factory packaging:
Dimensions: (19.5 x 6.0 x 6.0) cm
Weight: 539g
Manufacturer: Caithec